Part Number 50DR-063 Specification |
|||
---|---|---|---|
Part Number: 50DR-063 | Manufacturer: Jfw Industries Incorporated | Item Name : attenuator variable | |
NSN: 5985-01-508-8589 | FSC : 5985 Antennas Waveguides and Related Equipment | CAGE Code: 61162 | |
Alternate P/N : 50DR063 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 2 CONNECTOR, COAXIAL, FEMALE |
BNGR | FREQUENCY RANGE | 0.000 HERTZ MINIMUM AND 1100.000 MEGAHERTZ MAXIMUM |
AAFS | APPLICATION DESIGN | TRANSMISSION LINE |
AAQL | BODY STYLE | COAXIAL TYPE |
ABHP | OVERALL LENGTH | 4.720 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.760 INCHES NOMINAL |
ASYC | INSERTION LOSS AT MINIMUM ATTENUATION IN MAXIMUM DECIBELS | 0.5 |
ASYD | OVERALL ATTENUATION RANGE IN DECIBELS | +0.0/+50.0 |
CRSJ | SHAFT TYPE | ROUND, HOLLOWED |
CQTQ | ADJUSTMENT DEVICE TYPE AND QUANTITY | 1 SHAFT |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | SMA |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -20.0/+85.0 DEG CELSIUS |
ABMK | OVERALL WIDTH | 1.500 INCHES NOMINAL |