| Item Name | Filter Radio Freque |
| INC Code | 00765 |
| Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
| Federal Supply Class (FSC) | 5915 Filters and Networks |
| National Item Identification Number (NIIN) | 00-246-0596 (002460596) |
| NCB Code | USA (00) |
| Manufacturer | Bae Systems Inc, Br Communications Inc, Corcom Inc, Cornell Dubilier Marketing Inc, Gould Instrument Systems Inc, Stanford Applied Engineering Inc, Jpi Transportation Products Inc, Cornell Dubilier Electronics Corp, Sprague Electric Co, U S Army Aviation And Missile |
| Associated Parts Numbers of NSN 5915-00-246-0596 | ||||||
|---|---|---|---|---|---|---|
| Part Number | Manufacturer | Item Name | Cage Code | Type | Status | RFQ |
| 1056819P1 | bae systems inc | filter radio freque | 94117 | A | A | RFQ |
| 9100-0036 | br communications inc | filter radio freque | 33783 | A | A | RFQ |
| 2B1-2A | corcom inc | filter radio freque | 05245 | A | A | RFQ |
| 2B1E | corcom inc | filter radio freque | 05245 | A | A | RFQ |
| APF2116 | cornell dubilier marketing inc | filter radio freque | 00853 | A | A | RFQ |
| APF211L | cornell dubilier marketing inc | filter radio freque | 00853 | A | A | RFQ |
| 286015-1 | gould instrument systems inc | filter radio freque | 96795 | A | A | RFQ |
| GA1A-2 | stanford applied engineering inc | filter radio freque | 23880 | A | A | RFQ |
| 286015-1 | jpi transportation products inc | filter radio freque | 0ax87 | A | H | RFQ |
| APF211L | cornell dubilier electronics corp | filter radio freque | 14655 | A | R | RFQ |
| APF2116 | cornell dubilier electronics corp | filter radio freque | 14655 | A | R | RFQ |
| 2JX5102A | sprague electric co | filter radio freque | 56289 | A | A | RFQ |
| P15733-025-01 | u s army aviation and missile | filter radio freque | 18876 | H | A | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 0.625 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 2.250 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.750 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.875 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.130 INCHES NOMINAL |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG GROUND 3RD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 230.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 230.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 2.1 KILOVOLTS AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Relevant Components for NSN - 5915-00-246-0596, 5915002460596 | ||||
| 5915-00-916-6102 (5915009166102) | 5915-01-024-4216 (5915010244216) | 5915-00-506-7221 (5915005067221) | 5915-01-296-1491 (5915012961491) | |
| 5915-01-257-4714 (5915012574714) | 5915-01-223-3639 (5915012233639) | 5915-01-418-9652 (5915014189652) | 5915-01-463-7765 (5915014637765) | |
| 5915-01-448-6594 (5915014486594) | 5915-01-096-8852 (5915010968852) | 5915-01-281-0448 (5915012810448) | 5915-01-150-8771 (5915011508771) | |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!