| Item Name | Filter Radio Freque |
| INC Code | 00765 |
| Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
| Federal Supply Class (FSC) | 5915 Filters and Networks |
| National Item Identification Number (NIIN) | 01-025-0861 (010250861) |
| NCB Code | USA (01) |
| Manufacturer | Genisco Filter Corp, Northrop Grumman Systems Corporation, Sora Power Inc, Spectrum Control Inc |
| Associated Parts Numbers of NSN 5915-01-025-0861 | ||||||
|---|---|---|---|---|---|---|
| Part Number | Manufacturer | Item Name | Cage Code | Type | Status | RFQ |
| GF-55623 | genisco filter corp | filter radio freque | 07294 | A | A | RFQ |
| 905557-1 | northrop grumman systems corporation | filter radio freque | 06481 | A | A | RFQ |
| 791703-PIECE 114 | northrop grumman systems corporation | filter radio freque | 06481 | A | A | RFQ |
| 10 B 612 | sora power inc | filter radio freque | 13058 | A | A | RFQ |
| GF-55623 | spectrum control inc | filter radio freque | 13050 | F | A | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 11.000 INCHES MAXIMUM |
| ABKW | OVERALL HEIGHT | 3.500 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 8.000 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.276 INCHES MINIMUM AND 0.283 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 9.000 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 78.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 11.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 11.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 11.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 14.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 14.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHCG | MAXIMUM TEMP RISE | 40.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD GROUND 3RD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 THREADED STUD INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 THREADED STUD OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 150.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 150.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Relevant Components for NSN - 5915-01-025-0861, 5915010250861 | ||||
| 5915-00-916-6102 (5915009166102) | 5915-01-024-4216 (5915010244216) | 5915-00-506-7221 (5915005067221) | 5915-01-296-1491 (5915012961491) | |
| 5915-01-257-4714 (5915012574714) | 5915-01-223-3639 (5915012233639) | 5915-01-418-9652 (5915014189652) | 5915-01-463-7765 (5915014637765) | |
| 5915-01-448-6594 (5915014486594) | 5915-01-096-8852 (5915010968852) | 5915-01-281-0448 (5915012810448) | 5915-01-150-8771 (5915011508771) | |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote