Part Number ANE2HW100-6A Specification |
|||
---|---|---|---|
Part Number: ANE2HW100-6A | Manufacturer: allied refrigeration inc | Item Name : valve expansion | |
NSN: 4820001894843 | FSC : 4820 Valves Nonpowered | CAGE Code: 83994 | |
Alternate P/N : ANE2HW1006A |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
4820-00-189-4843 Item Description: Valve Expansion | 4820 | 001894843 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ane2hw100-6a | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
EXPANSION | AAFZ | BODY MATERIALBRASS |
EXPANSION | AAQL | BODY STYLESTRAIGHT THRU |
EXPANSION | ABJH | TEMP RATING160 0 DEG FAHRENHEIT |
EXPANSION | ACKL | MEDIA FOR WHICH DESIGNEDREFRIGERANT 22 |
EXPANSION | ACKM | FIRST END CONNECTION TYPEUNTHREADED INTERNAL TUBE |
EXPANSION | ACKN | FIRST END STYLE DESIGNATORSOCKET |
EXPANSION | ACLH | FIRST END OUTSIDE DIAMETER TUBE ACCOMMODATED0 500 INCHES NOMINAL |
EXPANSION | ACLR | SECOND END RELATIONSHIP WITH FIRST ENDNOT IDENTICAL |
EXPANSION | ACLS | SECOND END CONNECTION TYPEUNTHREADED INTERNAL TUBE |
EXPANSION | ACLT | SECOND END STYLE DESIGNATORSOCKET |
EXPANSION | ACMP | SECOND END OUTSIDE DIAMETER TUBE ACCOMMODATED0 380 INCHES NOMINAL |
EXPANSION | ADQU | FLOW CONTROL DEVICEDIAPHRAGM |
EXPANSION | ADQV | FLOW CONTROL DEVICE MATERIALSTEEL CORROSION RESISTING |
EXPANSION | ADQZ | END CONNECTION QUANTITY2 |
EXPANSION | AEVT | CAPILLARY TUBE LENGTH30 000 INCHES NOMINAL |
EXPANSION | AEVU | BULB LENGTH3 500 INCHES NOMINAL |
EXPANSION | AEVV | BULB DIAMETER0 500 INCHES NOMINAL |
EXPANSION | AFKK | VALVE EXPANSION CONTROL TYPETHERMOSTATIC |
EXPANSION | AFKL | VALVE EVAPORATOR TEMP RANGE DESIGNATIONHIGH |
EXPANSION | AFKM | VALVE PRESSURE LIMITING DEVICEINCLUDED |
EXPANSION | AFKN | VALVE PRESSURE LIMITING DEVICE SETTING400 0 POUNDS PER SQUARE INCH GAGE |
EXPANSION | AFKQ | BULB MEDIA TYPEREFRIGERANT 22 |
EXPANSION | AFKU | VALVE EQUALIZER LOCATIONINTERNAL |
EXPANSION | AGUB | REFRIGERATION CAPACITY IN BTU PER HOUR24 0 |
EXPANSION | TEST | TEST DATA DOCUMENT97403-13216E6160 DRAWING THIS IS THE BASIC GOVERNING DRAWING SUCH AS A CONTRACTOR DRAWING ORIGINAL EQUIPMENT MANUFACTURER DRAWING ETC EXCLUDES ANY SPECIFICATION STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |
Related NSN Components to ANE2HW100-6A |
|||
---|---|---|---|
ANE-001 | ANE-I-FC-1 4-ODF EE-3 8X5 8 OD | ANE-K3L-G-04 | ANE0007 |
ANE1-114-9 | ANE1084 | ANE1084-DCDT | ANE1085 |
ANE11-500-9 | ANE11-624-10 | ANE11-624-8 | ANE11-624-9 |
ANE12M8 | ANE2-M6 | ANE255-10 | ANE29-845-10 |
ANE29-845-11 | ANE2M10 | ANE2M4 | ANE2P12 |
ANE3009P00RN | ANE34-625 | ANE356-8 | ANE356-9 |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote