We've received your request for BX 2300A (described as Transformer Power), manufactured by Baltimore Transformer Company with CAGE code 85323. This part is registered under NSN 5950-00-804-2916, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5950 Coils and Transformers. Our verification process will confirm traceability through supporting identifiers including NIIN 00-804-2916, NCB code 00 (origin: USA), and INC 32496. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your BX 2300A requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-804-2916 Item PartTypeName: TRANSFORMER,POWER | 5950 | 008042916 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 1791974 | 6 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAU | BODY HEIGHT | 4.625 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 9 SECONDARY SINGLE COMPONENT |
| CRMJ | WINDING POWER RATING | 26.14 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| CRMJ | WINDING POWER RATING | 6.615 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 3.750 INCHES NOMINAL |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABMK | OVERALL WIDTH | 3.250 INCHES NOMINAL |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.05 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 1.05 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 4.15 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRMJ | WINDING POWER RATING | 10.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 6.615 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 22 TURRET |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |
| AAC | X |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 063420 - Transformers, noi, or transformer par |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!