We've received your request for 9675-0-F3 (described as Switch Pressure), manufactured by Barksdale Inc with CAGE code 89326. This part is registered under NSN 5930-01-200-8564, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5930 Switches. Our verification process will confirm traceability through supporting identifiers including NIIN 01-200-8564, NCB code 01 (origin: USA), and INC 00206. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your 9675-0-F3 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-01-200-8564 Item PartTypeName: SWITCH,PRESSURE | 5930 | 012008564 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 9675-0-F3 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS PROOF AND SALT SPRAY PROOF |
| ABKW | OVERALL HEIGHT | 5.750 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 2.370 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.720 INCHES NOMINAL |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.720 INCHES NOMINAL |
| AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
| AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| CQJB | PROOF PRESSURE | 3000.00 POUNDS PER SQUARE INCH |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
| CQJX | NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED HOLE |
| CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE,PRESET AND DEACTUATION POINT ADJUSTABLE,PRESET |
| CTYM | CONTACT ADJUSTMENT RANGE | 5.00 TO 20.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW |
| CTYX | CONTACT STIMULUS RATING | 20.00 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND 200.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND 20.00 DEACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND 180.00 DEACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
| CTZL | PRESSURE CONNECTOR TYPE | SWIVEL NUT,COMPRESSION,THREADED INTERNAL SINGLE CONNECTION |
| FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| FREQ | FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
| FREQ | FREQUENCY IN HERTZ | 60.0 THIRD VOLTAGE |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| STYL | STYLE DESIGNATOR | RECTANGULAR |
| THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
| THSD | THREAD SERIES DESIGNATOR | NPT SINGLE THREADED HOLE |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
| SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!