We've received your request for JD2 A3A16 DU (described as Circuit Breaker), manufactured by Eaton Corporation with CAGE code 74193. This part is registered under NSN 5925-01-174-7493, classified in FSG / FSC . Our verification process will confirm traceability through supporting identifiers including NIIN 01-174-7493, NCB code 01 (origin: USA), and INC 00136. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your JD2 A3A16 DU requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-174-7493 Item PartTypeName: CIRCUIT BREAKER | 5925 | 011747493 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 2567-218 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ABXD | BUSHING LENGTH | 0.625 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.250 INCHES NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.560 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.843 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 2 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 0.05 MILLIAMPERES AC SECOND LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 6.0 AMPERES AC FIRST LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 PUSH BUTTON |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SECOND LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.300 MINIMUM AT 200 PCT AND 5.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT |
| CTJS | UNPACKAGED UNIT WEIGHT | 0.312 POUNDS NOMINAL |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNC |
| TTQY | TERMINAL TYPE AND QUANTITY | 4 CLIP |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | X |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!