Buy FA60-1074 Filter Radio Freque part by Ems Development Corporation

Part Number:  FA60-1074
Alternate P/N:  FA601074
Manufacturer:  ems development corporation
NIIN:  011878020
Item Name :  filter radio freque
CAGE Code:  13619
INC Code:  00765
Country:  USA
NCB Code:  01

We've received your request for FA60-1074 (described as Filter Radio Freque), manufactured by Ems Development Corporation with CAGE code 13619. This part is registered under NSN 5915-01-187-8020, classified in FSG / FSC . Our verification process will confirm traceability through supporting identifiers including NIIN 01-187-8020, NCB code 01 (origin: USA), and INC 00765. Please submit your formal quotation request to proceed.

Thank you for choosing Aerospace Exchange for your FA60-1074 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.

Note : We Will Not Share Your Information To Any Third Parties.

Please fill out below form for FA60-1074

Contact Information

“*” Required Fields Are Compulsory
   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

How to Begin the Quotation Process

  1. Fill out and submit the form for part FA60-1074, on this page with details like your required quality and target pricing included.
  2. Our staff will receive and review your information, quickly formulating fitting solutions based on your specifications.
  3. Within 15 minutes or less, an account manager will contact you to present options and discuss how you can proceed with procurement.

NSN Information for Part Number FA60-1074 with NSN 5915-01-187-8020, 5915011878020

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5915-01-187-8020

Item PartTypeName:

FILTER,RADIO FREQUENCY INTERFERE

59150118780200P
CIICHCCESDPMICCriticalityENAC
7 A
Part NumberISCRNVCRNCCHCCMSDSSADC
5389072623

Characteristics Data of NSN 5915-01-187-8020, 5915011878020

MRCCriteriaCharacteristic
ABKWOVERALL HEIGHT6.000 INCHES MAXIMUM
ADAQBODY LENGTH7.000 INCHES MAXIMUM
ADATBODY WIDTH3.430 INCHES NOMINAL
ADAUBODY HEIGHT5.000 INCHES MAXIMUM
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH7.500 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.430 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-0.0 TO 65.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS18.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS18.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB,SOLDER LUG GROUND 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB,SOLDER LUG INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CTJSUNPACKAGED UNIT WEIGHT10.000 POUNDS NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE

Schedule B & Trade

End Use : 41210 Stereo equipment, etc.
Schedule B : 8527995030 (NAICS 334310) Reception apparatus, nesoi
SITC : 76289 Radiobroadcast receivers, not combined with sound recording or reproducing apparatus nor with a clock, etc., n.E.S.

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC Z
Classification Control 7
MGMT_CTL 9b-----
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061990 - Electrical equip: filters
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components

Semiconductor’s Certifications and Memberships

Thank You for Your Visit.

Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top