We've received your request for FA9017 (described as Filter Radio Freque), manufactured by Ems Development Corporation with CAGE code 13619. This part is registered under NSN 5915-00-770-9941, classified in FSG / FSC . Our verification process will confirm traceability through supporting identifiers including NIIN 00-770-9941, NCB code 00 (origin: USA), and INC 00765. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your FA9017 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5915-00-770-9941 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 007709941 | 0 | Y | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| C17805 | 2 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABKW | OVERALL HEIGHT | 1.797 INCHES MINIMUM AND 1.874 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 1.344 INCHES MINIMUM AND 1.468 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 8.057 INCHES MINIMUM AND 8.067 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.531 INCHES MINIMUM AND 1.593 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 1.750 INCHES MINIMUM AND 1.765 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.734 INCHES MINIMUM AND 5.766 INCHES MAXIMUM |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 97814 |
| AHBP | INPUT TERMINAL IDENTIFICATION | 8003-145-7P-FP |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG GROUND 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
| End Use : 41210 | Stereo equipment, etc. |
|---|---|
| Schedule B : 8527995030 (NAICS 334310) | Reception apparatus, nesoi |
| SITC : 76289 | Radiobroadcast receivers, not combined with sound recording or reproducing apparatus nor with a clock, etc., n.E.S. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | Y - Indicates information is in the hazardous materials information resource system (hmirs). |
| PMIC | U - Precious metal content is unknown |
| AAC | V |
|---|---|
| Classification Control | U |
| MGMT_CTL | 12e2--1 |
| Quantity per pack | 1 |
| Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061990 - Electrical equip: filters |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!