We've received your request for FC 594 (described as Filter Radio Freque), manufactured by Fil Coil Inc with CAGE code 56528. This part is registered under NSN 5915-00-656-6976, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5915 Filters and Networks. Our verification process will confirm traceability through supporting identifiers including NIIN 00-656-6976, NCB code 00 (origin: USA), and INC 00765. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your FC 594 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5915-00-656-6976 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 006566976 | 0 | Y | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| B8485 | 2 | 2 | 1 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 4.810 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 2.600 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.060 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.560 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.241 INCHES MINIMUM AND 0.247 INCHES MAXIMUM |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 1ST RADIO INTERFERENCE AND 4.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 2ND RADIO INTERFERENCE AND 4.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 3RD RADIO INTERFERENCE AND 4.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 4TH RADIO INTERFERENCE AND 4.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 5TH RADIO INTERFERENCE AND 4.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 6TH RADIO INTERFERENCE AND 4.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 07639 |
| AHBP | INPUT TERMINAL IDENTIFICATION | MS3102A-24-25 |
| AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
| AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
| AHCK | FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 3.0 AND 5.0 AND 20.0 AND 40.0 AND 65.0 AND 80.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| CBBL | FEATURES PROVIDED | NUT AND WASHER |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 THREADED STUD OUTPUT 2ND FUNCTION |
| CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 250.0 VOLTS AT SEA LEVEL |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 3RD RADIO INTERFERENCE AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 4TH RADIO INTERFERENCE AND 400.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 5TH RADIO INTERFERENCE AND 400.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 6TH RADIO INTERFERENCE AND 400.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 800.0 VOLTS AT SEA LEVEL |
| FEAT | SPECIAL FEATURES | SIX FILTERED FUNCTIONS |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| ZZZK | SPECIFICATION/STANDARD DATA | 07639-B8485 MANUFACTURERS SOURCE CONTROL |
| End Use : 41210 | Stereo equipment, etc. |
|---|---|
| Schedule B : 8527995030 (NAICS 334310) | Reception apparatus, nesoi |
| SITC : 76289 | Radiobroadcast receivers, not combined with sound recording or reproducing apparatus nor with a clock, etc., n.E.S. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | Y - Indicates information is in the hazardous materials information resource system (hmirs). |
| PMIC | A - Item does not contain precious metal. |
| AAC | Z |
|---|---|
| Classification Control | U |
| MGMT_CTL | Q2200x- |
| Quantity per pack | 1 |
| Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061990 - Electrical equip: filters |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote