Part Number 151E Specification |
|||
---|---|---|---|
Part Number: 151E | Manufacturer: General Electric Inc | Item Name : resistor fixed wire | |
NSN: 5905-00-552-2834 | FSC : 5905 Resistors | CAGE Code: 24449 |
MRC | Criteria | Characteristic |
---|---|---|
ABJT | TERMINAL LENGTH | 1.370 INCHES MINIMUM AND 1.620 INCHES MAXIMUM |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -30.0 TO 30.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AAPP | ELECTRICAL RESISTANCE | 10.000 OHMS |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 40.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+250.0 |
AARB | TERMINAL TYPE | WIRE LEAD |
ABPM | BODY DIAMETER | 0.170 INCHES MINIMUM AND 0.230 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.470 INCHES MINIMUM AND 0.560 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |