Buy 9922S50-2XA Filter Radio Freque part by Greatbatch Sierra Inc

Part Number:  9922S50-2XA
Alternate P/N:  9922S502XA
Manufacturer:  greatbatch sierra inc
NIIN:  013396647
Item Name :  filter radio freque
CAGE Code:  79474
INC Code:  00765
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components

We've received your request for 9922S50-2XA (described as Filter Radio Freque), manufactured by Greatbatch Sierra Inc with CAGE code 79474. This part is registered under NSN 5915-01-339-6647, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5915 Filters and Networks. Our verification process will confirm traceability through supporting identifiers including NIIN 01-339-6647, NCB code 01 (origin: USA), and INC 00765. Please submit your formal quotation request to proceed.

Thank you for choosing Aerospace Exchange for your 9922S50-2XA requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.

Note : We Will Not Share Your Information To Any Third Parties.

Please fill out below form for 9922S50-2XA

Contact Information

“*” Required Fields Are Compulsory
   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

How to Begin the Quotation Process

  1. Fill out and submit the form for part 9922S50-2XA, on this page with details like your required quality and target pricing included.
  2. Our staff will receive and review your information, quickly formulating fitting solutions based on your specifications.
  3. Within 15 minutes or less, an account manager will contact you to present options and discuss how you can proceed with procurement.

NSN Information for Part Number 9922S50-2XA with NSN 5915-01-339-6647, 5915013396647

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5915-01-339-6647

Item PartTypeName:

FILTER,RADIO FREQUENCY INTERFERE

59150133966470P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
841795-01695

Characteristics Data of NSN 5915-01-339-6647, 5915013396647

MRCCriteriaCharacteristic
ABKWOVERALL HEIGHT2.700 INCHES MAXIMUM
ADAQBODY LENGTH5.000 INCHES MAXIMUM
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 1ST RADIO INTERFERENCE AND 0.05 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 2ND RADIO INTERFERENCE AND 0.05 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 3RD RADIO INTERFERENCE AND 0.05 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 4TH RADIO INTERFERENCE AND 0.05 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 6TH RADIO INTERFERENCE AND 0.1 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBSOUTPUT TERMINAL MANUFACTURER CODE13973
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
AKNAINCLOSURE TYPEHERMETICALLY SEALED
CQJXNOMINAL THREAD SIZE0.190 INCHES
CRSTBODY SURFACE TREATMENTTIN
ABHPOVERALL LENGTH5.700 INCHES MAXIMUM
ADATBODY WIDTH4.620 INCHES MAXIMUM
ADAUBODY HEIGHT2.000 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.320 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-28.0 TO 85.0 DEG CELSIUS
AFSVAVERAGE LIFE RATING IN HOURS1000.0
AGAVEND ITEM IDENTIFICATIONTACTICAL AIR OPERATIONS MODULE AN/TYQ-23(V)1
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 5TH RADIO INTERFERENCE AND 0.1 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE13973
AHBPINPUT TERMINAL IDENTIFICATIONBNC-CONNECTOR
AHBTOUTPUT TERMINAL IDENTIFICATIONBNC-RECEPTACLE
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS3.0 AND 10.0 AND 40.0 AND 60.0 AND 70.0 AND 90.0
CBBLFEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 CONNECTOR,PLUG INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 1ST RADIO INTERFERENCE AND 50.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 2ND RADIO INTERFERENCE AND 50.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 3RD RADIO INTERFERENCE AND 50.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 4TH RADIO INTERFERENCE AND 50.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 6TH RADIO INTERFERENCE AND 50.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
CQRGBODY MATERIALMETAL
CTJSUNPACKAGED UNIT WEIGHT4.410 POUNDS NOMINAL
FEATSPECIAL FEATURESTWENTY-TWO FILTERED FUNCTIONS
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE125.0 VOLTS AT SEA LEVEL
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 5TH RADIO INTERFERENCE AND 50.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE125.0 VOLTS AT SEA LEVEL

Schedule B & Trade

End Use : 41210 Stereo equipment, etc.
Schedule B : 8527995030 (NAICS 334310) Reception apparatus, nesoi
SITC : 76289 Radiobroadcast receivers, not combined with sound recording or reproducing apparatus nor with a clock, etc., n.E.S.

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL 12b2--1
Quantity per pack 1
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061990 - Electrical equip: filters
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components

Semiconductor’s Certifications and Memberships

Thank You for Your Visit.

Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top