Part Number 2TL1-10F Specification |
|||
---|---|---|---|
Part Number: 2TL1-10F | Manufacturer: Honeywell Control Systems Ltd | Item Name : switch toggle | |
NSN: 5930-01-481-1109 | FSC : 5930 Switches | CAGE Code: U4042 | |
Alternate P/N : 2TL110F |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 0.910 INCHES MAXIMUM |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-S-3950 |
ADAQ | BODY LENGTH | 1.340 INCHES MAXIMUM |
SR-1 | SPEC/STD CONTROLLING DATA | |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MS27408-4F |
AFUY | ACTUATOR POSITION-LOCKING RELATIONSHIP | UP POSITION LOCKED IN |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
SR-1 | MANUFACTURERS CODE | 81349 |
FEAT | SPECIAL FEATURES | 2 POLE |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.370 INCHES MAXIMUM |
AAQL | BODY STYLE | BUSHING MOUNT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.000 AMPERES INDUCTIVE DC AND 15.000 AMPERES INDUCTIVE AC |