We've received your request for S83241 (described as Switch Pressure), manufactured by Hydra Electric Company with CAGE code 98505. This part is registered under NSN 5930-01-090-5607, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5930 Switches. Our verification process will confirm traceability through supporting identifiers including NIIN 01-090-5607, NCB code 01 (origin: USA), and INC 00206. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your S83241 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-01-090-5607 Item PartTypeName: SWITCH,PRESSURE | 5930 | 010905607 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 252504 | 5 | 1 | C | A |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJD | THREAD CLASS | 3A ALL PRESSURE CONNECTION |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE PROOF |
| ABHP | OVERALL LENGTH | 4.211 INCHES NOMINAL |
| ABKV | OUTSIDE DIAMETER | 0.438 INCHES NOMINAL ALL CONNECTIONS |
| ABKW | OVERALL HEIGHT | 2.750 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 3.380 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.000 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | AMCS 82577 |
| AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
| AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| AXGY | MOUNTING METHOD | OUTLET CONNECTION |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| CMLP | THREAD QUANTITY PER INCH | 20 ALL PRESSURE CONNECTION |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJB | PROOF PRESSURE | 250.00 POUNDS PER SQUARE INCH GAGE |
| CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CSCC | SENSING ELEMENT BURST PRESSURE | 500.00 POUNDS PER SQUARE INCH GAGE |
| CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
| CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND 500.0 MILLIAMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND 500.0 MILLIAMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | 0.30 ACTUATION POINT MAXIMUM GALLONS PER MINUTE AND 0.20 DEACTUATION POINT MINIMUM GALLONS PER MINUTE AND 0.10 DIFFERENTIAL POINT NOMINAL GALLONS PER MINUTE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 6.0 DC AT SEA LEVEL SECOND VOLTAGE |
| CTZL | PRESSURE CONNECTOR TYPE | FLARED,THREADED EXTERNAL ALL CONNECTIONS |
| FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
| STYL | STYLE DESIGNATOR | RECTANGULAR |
| THSD | THREAD SERIES DESIGNATOR | UNF ALL PRESSURE CONNECTION |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
| SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote