Part Number 130-136-3 Specification |
|||
---|---|---|---|
Part Number: 130-136-3 | Manufacturer: Melstrom Manufacturing Corporation | Item Name : resistor fixed wire | |
NSN: 5905-00-500-7502 | FSC : 5905 Resistors | CAGE Code: 93953 | |
Alternate P/N : 1301363 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -500.0 TO 500.0 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 40.0 |
ABJT | TERMINAL LENGTH | 1.000 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.125 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
AAPP | ELECTRICAL RESISTANCE | 20.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/+5.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 250.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+235.0 |
AAQZ | INCLOSURE METHOD | HERMETICALLY SEALED |
AARB | TERMINAL TYPE | FERRULE |
ADAQ | BODY LENGTH | 5.000 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 70.000 FREE AIR |