Part Number 48-2-S14-LN2-10 Specification |
|||
---|---|---|---|
Part Number: 48-2-S14-LN2-10 | Manufacturer: Oakland Industries Ltd | Item Name : circuit breaker | |
NSN: 5925-01-325-4404 | FSC : 5925 Circuit Breakers | CAGE Code: 06402 | |
Alternate P/N : 482S14LN210 |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-325-4404 Item Description: Circuit Breaker | 5925 | 013254404 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
48-2-S14-Ln2-10 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAT | BODY WIDTH | 0.710 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.930 INCHES NOMINAL |
AEFN | NONTURN DEVICE LOCATION | AT 12 OCLOCK |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.730 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.480 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
ABXD | BUSHING LENGTH | 0.260 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.220 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEFQ | NONTURN DEVICE LENGTH | 0.060 INCHES NOMINAL |
AEFR | NONTURN DEVICE WIDTH | 0.110 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SINGLE LOCATION AND 10.0 AMPERES DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF AND VIBRATIONPROOF AND CORROSION RESISTANT AND HUMIDITY PROOF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
Related NSN Components to 48-2-S14-LN2-10 |
|||
---|---|---|---|
48-00-0050 | 48-00-0050 | 48 00 0543 | 48-00-0547 |
48-00-0552 | 48 00 0579 | 48-00-0579M | 48-00-1013 |
48-00-1014 | 48-00-1031 | 48-00-1041 | 48-00-1063 |
48-00-1066 | 48-00-1068 | 48-00-1171 | 48-00-1172 |
48-00-1174 | 48-00-1176 | 48-00-1178 | 48-00-1179 |
48-00-1182 | 48-00-1183 | 48-00-1184 | 48-00-1401 |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote