We've received your request for 32378 (described as Switch Pressure), manufactured by Ranco Management Corp with CAGE code 49742. This part is registered under NSN 5930-00-538-3406, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5930 Switches. Our verification process will confirm traceability through supporting identifiers including NIIN 00-538-3406, NCB code 00 (origin: USA), and INC 00206. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your 32378 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-00-538-3406 Item PartTypeName: SWITCH,PRESSURE | 5930 | 005383406 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 012-1546 | 2 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM |
| ABKW | OVERALL HEIGHT | 4.656 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 1.906 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.656 INCHES MAXIMUM |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.406 INCHES NOMINAL |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.500 INCHES NOMINAL |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.812 INCHES NOMINAL |
| AJZC | PRESSURE SWITCH TYPE | GAGE |
| AXGY | MOUNTING METHOD | FLUSH AND UNTHREADED HOLE |
| CMLP | THREAD QUANTITY PER INCH | 20 ALL PRESSURE CONNECTION |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJX | NOMINAL THREAD SIZE | 0.4375 INCHES SINGLE PRESSURE CONNECTION |
| CQYJ | MOUNTING FACILITY PATTERN | OBTUSE TRIANGLE |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
| CSCF | TERMINAL TYPE | TAB W/SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 4.3 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE,PRESET AND ACTUATION POINT ADJUSTABLE,PRESET |
| CTYM | CONTACT ADJUSTMENT RANGE | 100.00 TO 250.00 ACTUATION POINT POUNDS PER SQUARE INCH AND 85.00 TO 225.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| CTYX | CONTACT STIMULUS RATING | 15.00 DIFFERENTIAL POINT MINIMUM POUNDS PER SQUARE INCH AND 25.00 DIFFERENTIAL POINT MAXIMUM POUNDS PER SQUARE INCH |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CTZL | PRESSURE CONNECTOR TYPE | FLARED,THREADED EXTERNAL ALL CONNECTIONS |
| FEAT | SPECIAL FEATURES | SHORTEST VERTICAL DISTANCE BETWEEN MTG CENTERS 0.531 IN. |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| STYL | STYLE DESIGNATOR | RECTANGULAR |
| THSD | THREAD SERIES DESIGNATOR | UNC ALL PRESSURE CONNECTION |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
| SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf9eh-n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote