We've received your request for FTC 3408 (described as Transformer Power), manufactured by Transistor Devices Inc with CAGE code 3S657. This part is registered under NSN 5950-01-339-5097, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5950 Coils and Transformers. Our verification process will confirm traceability through supporting identifiers including NIIN 01-339-5097, NCB code 01 (origin: USA), and INC 32496. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your FTC 3408 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-339-5097 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013395097 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 35062-1 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABKW | OVERALL HEIGHT | 3.250 INCHES MAXIMUM |
| ABTD | MOUNTING SLOT WIDTH | 0.257 INCHES NOMINAL SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 0.05 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 15 TAB,SOLDER LUG |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | HUMIDITY RESISTANT |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| AEHZ | MAXIMUM OPERATING TEMP | 60.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 0.8 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CRMJ | WINDING POWER RATING | 200.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 3.880 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.180 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABMK | OVERALL WIDTH | 3.350 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 0.4 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 0.75 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CRMJ | WINDING POWER RATING | 1.75 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| CRMJ | WINDING POWER RATING | 140.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| CRMJ | WINDING POWER RATING | 16.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | WINDING POWER RATING | 30.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 250.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 35.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; 5 SECONDARY WINDINGS |
| CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 063420 - Transformers, noi, or transformer par |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote